Publication details

 

Digitized Two-Parameter Spectrometer for Neutron-Gamma Mixed Field

Basic information
Original title:Digitized Two-Parameter Spectrometer for Neutron-Gamma Mixed Field
Authors:Zdeněk Matěj, Václav Přenosil, Jiří Cvachovec, František Cvachovec
Further information
Citation:MATĚJ, Zdeněk, Václav PŘENOSIL, Jiří CVACHOVEC a František CVACHOVEC. Digitized Two-Parameter Spectrometer for Neutron-Gamma Mixed Field. Advances in Military Technology, Brno 2012: Univerzita obrany, 2012, Vol. 7, No. 1, s. 25-32. ISSN 1802-2308.Export BibTeX
@article{979787,
author = {Matěj, Zdeněk and Přenosil, Václav and Cvachovec, Jiří and Cvachovec, František},
article_location = {Brno 2012},
article_number = {No. 1},
keywords = {Two-parameter spectrometer; digitization; stilbene; pulse shape discrimination},
language = {eng},
issn = {1802-2308},
journal = {Advances in Military Technology},
title = {Digitized Two-Parameter Spectrometer for Neutron-Gamma Mixed Field},
volume = {Vol. 7},
year = {2012}
}
Original language:English
Field:Computer hardware and software
Type:Article in Periodical
Keywords:Two-parameter spectrometer; digitization; stilbene; pulse shape discrimination
Attached files:link to a new window2011 12 19 AiMT article a.pdf

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source 252Cf is presented.