A new modified technique for the treatment of high-risk prethreshold ROP under the direct visual control of RetCam 3

Autoři

TIMKOVIČ Juraj NĚMČANSKÝ Jan CHOLEVÍK Dalibor MAŠEK Petr AUTRATA Rudolf KREJČÍŘOVÁ Inka

Rok publikování 2015
Druh Článek v odborném periodiku
Časopis / Zdroj Biomedical Papers
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
www http://biomed.papers.upol.cz/artkey/bio-201503-0013_A_new_modified_technique_for_the_treatment_of_high-risk_prethreshold_ROP_under_the_direct_visual_control_of_Ret.php
Doi http://dx.doi.org/10.5507/bp.2015.027
Obor ORL, oftalmologie, stomatologie
Klíčová slova retinopathy of prematurity;laser photocoagulation;cryotherapy;RetCam photography
Popis Purpose: To describe a new modified technique in the treatment of ROP (retinopathy of prematurity) using the RetCam 3 digital imaging system - Camera-Assisted Laser photocoagulation and Cryotherapy of the Retina (CALCR). Methods: From Nov 2011 to Oct 2013, 113 infants were diagnosed with ROP. The average post-conceptual age (PCA) at the time of diagnosis was the 35th week of PCA; the average birth weight was 1,041 g. According to the ETROP study, the avascular part of the retina of infants with high-risk prethreshold ROP was treated with a trans-scleral diode laser or with cryotherapy within 48-72 h after the diagnosis. The intervention was performed under general anaesthesia under the direct visual control of the RetCam 3. Results: The CALCR technique was used in all 23 infants (46 eyes) diagnosed with high-risk prethreshold ROP. The average age of these infants at the time of the intervention was the 38th week of PCA. None of the infants had any serious complications during the CALCR procedure. In contrast to the traditional technique, CALCR offers many benefits: the image of the retina is real, magnified and not inverted, it shows details of the retina in a high resolution, photo and video documentation is available. Therefore the preoperative, intraoperative and postoperative condition of the retina can be precisely evaluated and compared on a fully standardized basis. Conclusions: The CALCR procedure represents a new technique providing greater accuracy when targeting the avascular part of the retina, enables better visualisation and more precise treatment, and reduces the risk of unintended damage to healthy retinal tissue.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info