Informace o publikaci

Factors affecting non-contact measuring of surface temperatures of the cave walls (Císařská Cave, Moravian Karst)

Autoři

LANG Marek FAIMON Jiří NAVRÁTIL Zdeněk ROUBAL Zdeněk ŠTELCL Jindřich GREGOROVÁ Markéta

Rok publikování 2026
Druh Konferenční abstrakty
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
Přiložené soubory
Popis Condensation corrosion represents a classic problem that has been continuously solved in karst caves for several decades. The water condensation process plays an important role in the formation of characteristic speleogenetic forms in a cave environment. Under suitable conditions, water vapor from the cave atmosphere condensed on the cave walls, where it forms water droplets or a continuous water film. Although the condensed water is in equilibrium with the current partial pressure of carbon dioxide, it can further dissolve them because of its unsaturation with the carbonates that form the cave walls. In this context, the surface temperature of the cave walls appears to be a key parameter, since water condensation occurs only if it drops below the dew point temperature (the saturation temperature of cave air at the current water vapor concentration). The surface temperature of cave walls is generally considered to be stable, but detailed studies tend to refute this claim and show the opposite, which can lead, e.g., to erroneous paleoclimatic reconstructions using cave speleothems. A relatively wide spectrum of (1) contact and (2) non-contact sensors is currently available for monitoring surface temperatures in cave environment. However, the values obtained by all these sensors can differ significantly at the same location. In this study, selected contact and non-contact sensors were tested in the dynamic Císařská Cave in the Moravian Karst with the aim of evaluating the possibilities of measuring wall surface temperatures with a non-contact thermometer. Monitoring took place from May 2023 to March 2026 and included a total of 14 campaigns under different external conditions, during which wall surface temperatures were monitored once at 11 selected sites to compile cave temperature profiles. The resulting trends of the individual time series showed a similar character for all sensors, but the measured values were different. Although the temperatures obtained by contact methods were relatively similar, the non-contact methods showed both higher (thermal camera) and lower (pyrometer) temperatures. The underestimated temperatures measured by the pyrometer indicated (i) natural influence, by the temperature difference between the external air and the cave air, but also (ii) anthropogenic influence, by the heat released from the operator’s hand. Using a pyrometer in a cave environment requires certain measures to eliminate the mentioned effects, such as a special handle on the pyrometer or its placement into the monitored environment for a period of several hours, ideally overnight before the measurement. The measured data demonstrated that contact methods are more suitable for measurement in cave environments but can only be used in accessible spaces. For monitoring of inaccessible passages, non-contact methods are necessary, but modified methods must be applied.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info