Publication details

Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures

Authors

ZWIPP Hans PAŠA Libor ŽILKA Luboš AMLANG Michael RAMMELT Stefan POMPACH Martin

Year of publication 2016
Type Article in Periodical
Magazine / Source Journal of Orthopaedic Trauma
MU Faculty or unit

Faculty of Medicine

Citation
Doi http://dx.doi.org/10.1097/BOT.0000000000000482
Field Traumatology and orthopaedic surgery
Keywords sinus tarsi approach; arthroscopy; fluoroscopy; calcaneal fracture; locking calcaneal nail
Description Objectives: To reduce the complication rate associated with open reduction and internal fixation of displaced intraarticular calcaneal fractures through extensile approaches, a locking nail system (C-Nail) was developed for internal fixation. Design: Prospective case–control study. Setting: Two level I trauma centers (university hospital) and 1 large regional hospital in the Czech Republic and Germany. Patients: One hundred three patients (89 male and 14 female; mean age, 45.6 years) with 106 calcaneal fractures were treated between February 2011 and October 2013. Intervention: In all 106 cases, the stainless steel C-Nail with a length of 65 mm, a diameter of 8 mm, and 7 locking options was used for internal fixation. Previous reduction of the posterior facet was performed in 15 cases percutaneously, assisted by arthroscopy and fluoroscopy, and in 91 cases by a sinus tarsi approach. The reduced joint surface was fixed by 1 or 2 compression screws. All other fragments were fixed after reduction and temporary K-wire fixation with the C-Nail introduced percutaneously through the tuberosity and 5 to 6 interlocking screws. The latter were introduced into the sustentacular, the tuberosity, and the anterior process fragments with an aiming device consisting of 3 arms. Main Outcome Measures: Patients were assessed for complications, restoration of Böhler angle, posterior facet reduction with postoperative computed tomography, and weight-bearing radiographs at 6 months. Functional outcome was assessed using the American Orthopaedic Foot & Ankle Society (AOFAS) ankle/hindfoot scale after 6 and 12 months for all patients. Results: Wound edge necrosis was seen in 2 cases (1.9%), and soft tissue infection was observed in 1 case (0.9%). Böhler angle improved from 7.3 degree preoperatively to 28.7 degree at 6 months. The posterior facet step-off was reduced from 5.3 mm preoperatively to 0.7 mm postoperatively. The average AOFAS score averaged 89.5 at 6-month and 92.6 at 12-month follow-up. Conclusions: The C-Nail is a new locking system for treatment of displaced intraarticular calcaneal fractures combining a primary stability with reduced soft tissue complications.

You are running an old browser version. We recommend updating your browser to its latest version.

More info