Publication details

Mechanobiological distinction of focal and conductive arrhythmias by AFM

Investor logo
Authors

PEŠL Martin SVĚRÁK Filip BECKEROVÁ Deborah VRANA Šimon KABANOV Daniil MÁCHAL Jan PŘIBYL Jan ROTREKL Vladimír

Year of publication 2026
Type Conference abstract
MU Faculty or unit

Faculty of Medicine

Citation
Description Background: Cardiac arrhythmias arise from either abnormal focal impulse formation or impaired action potential propagation. Current in vitro models and biosensors primarily focus on cellular electrophysiology, often neglecting the stochastic significance of events and the mechanobiological aspects of cardiac contractions. There is an unmet clinical need for sensitive platforms that can distinguish these distinct arrhythmic mechanisms through mechanical analysis. Purpose: This research aimed to develop a highly sensitive biosensor using human pluripotent stem cell (hPSC)­ derived dual­beating organoids combined with atomic force microscopy (AFM). The objective was to discriminate between focal and conductive arrhythmic contractions by monitoring the three­dimensional contractile movement and stochastic fluctuations of cardiac tissue. Methods: Two conductively coupled hPSC­derived beating organoids were monitored using an AFM triangular cantilever as a sensitive transducer. Contractile behaviour was assessed by measuring vertical (DFL) and lateral (LF) deflection data at 100 Hz. A novel analysis of regression residuals was employed to quantify stochastic fluctuations, distinguishing the vertical and lateral directions of movement. The system’s sensitivity was validated using pharmacological agents, including heptanol (gap junction uncoupler), lidocaine (sodium channel blocker), salbutamol (ß2­agonist), and aminophylline (phosphodiesterase inhibitor). Results: Synchronised beating produced predominantly vertical deflection, whereas desynchronised clusters induced significant torsional bending and lateral signals. Analysis of the variance of regression residuals revealed significantly higher stochastic fluctuations in unsynchronised clusters (SD: 0.89) compared to controls (SD: 0.56). Heptanol increased residual variance to SD 0.87, effectively modelling conduction blockade. Conversely, salbutamol and aminophylline reduced residual variance (SD 0.43 and 0.32 respectively), indicating improved conduction stability. The AFM­based transducer successfully discriminated focal from conductive arrhythmias on a single­beat basis. Conclusions: The dual­organoid AFM biosensor provides a robust platform for distinguishing arrhythmia mechanisms through mechanobiological analysis. By capturing stochastic, low­abundance arrhythmic events often missed by deterministic analyses, this approach enhances translational relevance for cardiotoxicity assessment and precision medicine in cardiovascular health.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.

More info