SELKER John S. THEVENAZ Luc HUWALD Hendrik MALLET Alfred LUXEMBURG Wim VAN DE GIESEN Nick STEJSKAL Martin ZEMAN Josef WESTHOFF Martijn PARLANGE Marc B.

Rok publikování 2006
Druh Článek v odborném periodiku
Časopis / Zdroj Water Resources Research
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www http://www.agu.org/journals/wr/
Obor Geochemie
Klíčová slova fiber optic; temperature profile
Popis Five illustrative applications demonstrate configurations where the distributed temperature sensing (DTS) approach could be used: (1) lake bottom temperatures using existing communication cables, (2) temperature profile with depth in a 1400 m deep decommissioned mine shaft, (3) air-snow interface temperature profile above a snow-covered glacier, (4) air-water interfacial temperature in a lake, and (5) temperature distribution along a first-order stream. In examples 3 and 4 it is shown that by winding the fiber around a cylinder, vertical spatial resolution of millimeters can be achieved. These tools may be of exceptional utility in observing a broad range of hydrologic processes, including evaporation, infiltration, limnology, and the local and overall energy budget spanning scales from 0.003 to 30,000 m. This range of scales corresponds well with many of the areas of greatest opportunity for discovery in hydrologic science.