Zde se nacházíte:
Informace o publikaci
Digital Dose Rate Equivalent Meter for Neutron-Gamma Mixed Field
| Autoři | |
|---|---|
| Rok publikování | 2022 |
| Druh | Článek ve sborníku |
| Konference | IEEE Sensors |
| Fakulta / Pracoviště MU | |
| Citace | |
| www | https://ieeexplore.ieee.org/document/9967214 |
| Doi | https://doi.org/10.1109/SENSORS52175.2022.9967214 |
| Klíčová slova | Meters; Neutrons; Metrology; Sensor systems; Sensors; Velocity measurement; Radiation protection |
| Popis | A newly developed fast digital dose rate equivalent meter of H*(10) for neutron-gamma measurement is presented. The digital dose rate equivalent meter is built as a unique system allowing the measurement of ambient dose rate equivalent from neutron and gamma radiation separately into two channels. |